UT2UK 1.1 1 The **patune** utility is an interactive console program for calibrating and configuring the parameters of the Power Amplifier (PA) in the Ermak TT transceiver. The program provides bias control of the amplifier, stage current calibration, monitoring, and cooling system configuration.
2
3 ## Purpose of the Utility
4
5 The program is designed for engineers and technicians for:
6 * Automatic calibration of driver and output stage bias
7 * Setting target idle currents for each stage
8 * Monitoring the current status of the power amplifier
9 * Managing thermal compensation
10 * Configuring alarm parameters (temperature and current alarms)
11 * Setting up the fan control table (cooling)
12 * Saving configuration to non-volatile memory (NVMEM)
13
14 ### Operating Modes
15
16 The utility is organized as a hierarchical menu system:
17
UT2UK 2.1 18 ```
19 Main menu
20 ├── View information
21 │ ├── Print PA info (status)
22 │ ├── Print PA config (configuration)
23 │ ├── Print PA bias table (bias table)
24 │ └── Print total current (current consumption)
25 ├── Edit bias table
26 │ ├── Print PA bias table
27 │ ├── Reset all bias to defaults
28 │ ├── Enter driver stage current
29 │ ├── Enter output stage current
30 │ ├── Autotune DAC bias for driver stage
31 │ ├── Autotune DAC bias for output stage
32 │ ├── Enter driver stage thermo compensation
33 │ └── Enter output stage thermo compensation
34 ├── Edit PA configuration
35 │ ├── Print PA config
36 │ ├── Edit max temperature ALARM
37 │ ├── Edit restore temperature ALARM
38 │ ├── Edit max driver current
39 │ ├── Edit max output stage current
40 │ └── Fan Table Editor
41 │ ├── Print fan lookup table
42 │ ├── Reset fan table to defaults
43 │ └── Edit entries 0-7
44 ├── Quick commands
45 │ ├── Bias switch ON
46 │ ├── Bias switch OFF
47 │ ├── Reset overcurrent
48 │ └── Write all settings
49 ```
50
UT2UK 1.1 51 ## Command Line Parameters
52
53 The utility does not accept command line parameters. All control is performed through the interactive console menu.
54
55 ### Starting the Program
56
UT2UK 2.1 57 ```bash
58 patune
59 ```
60
UT2UK 1.1 61 At startup the program:
62 1. Connects to PA Manager
63 1. Requests the current PA configuration
64 1. Requests the current bias table
65 1. Displays the main menu
66 1. Waits for user input
67
68 ## Input Format
69
70 ### User Input
71
72 #### Numeric Input
73
74 When a numeric value is requested, the program expects:
75 * A positive integer within the specified range
UT2UK 2.1 76 * Or the `q` character to cancel the operation
77 * Or `q` and Enter to exit
UT2UK 1.1 78
79 Example of entering a current value:
80
UT2UK 2.1 81 ```bash
82 Enter driver stage current, mA (1-1000), press 'q' to cancel: 600
83 ```
84
UT2UK 1.1 85 **Validation:**
86 * The value must be within the range [min, max]
87 * If a value outside the range is entered, the program will display an error and repeat the prompt
88 * Maximum 1 attempt per second (1 sec delay)
89
90 #### Signed Numeric Values
91
92 Signed values are used for thermal compensation:
93
UT2UK 2.1 94 ```bash
95 Enter driver stage thermo compensation, C/dac (-100 - 100), press 'q' to cancel: -5
96 ```
97
UT2UK 1.1 98 **Valid value ranges:**
99 * Thermal compensation: -100 to +100 DAC/°C
100 * Temperature: -40 to 126 °C
101 * Fan speed: 0 to 100 %
102
103 #### Cancelling an Operation
104
UT2UK 2.1 105 Press `q` at any input prompt to cancel the current operation without saving.
UT2UK 1.1 106
107 ### Menu Navigation
108
UT2UK 2.1 109 * Digits `0-9` to select a menu item
UT2UK 1.1 110 * Enter to confirm
UT2UK 2.1 111 * `q` to return to the previous menu
UT2UK 1.1 112
113 ## Output Format
114
115 ### PA Status
116
UT2UK 2.1 117 ```bash
118 Print PA info.
119 Heat temp: 75C
120 Int temp: 65C
121 VSWR alarm : 0
122 Extra current alarm : 0
123 Temperature alarm : 0
124 Bias enable: 1
125 Bus voltage: 48mV
126 Output stage current: 1050mA
127 Driver stage current: 620mA
128 Output bias: 2450/2460mV
129 Driver bias: 1850/1855mV
130 Fan speed: 45
131 ```
UT2UK 1.1 132
UT2UK 2.1 133 | Field | Description | Unit |
134 | -------------------- | -------------------------------------------- | ------ |
135 | Heat temp | Heatsink temperature | °C |
136 | Int temp | Internal temperature | °C |
137 | VSWR alarm | VSWR alarm flag | 0/1 |
138 | Extra current alarm | Overcurrent alarm flag | 0/1 |
139 | Temperature alarm | Temperature alarm flag | 0/1 |
140 | Bias enable | Bias enable status | 0/1 |
141 | Bus voltage | Supply voltage | mV |
142 | Output stage current | Output stage current | mA |
143 | Driver stage current | Driver current | mA |
144 | Output bias | Output bias voltage (channel 0/1) | mV |
145 | Driver bias | Driver bias voltage (channel 0/1) | mV |
146 | Fan speed | Fan speed | % |
147
UT2UK 1.1 148 ### PA Configuration
149
UT2UK 2.1 150 ```bash
151 Print PA config.
152 High limit temp: 80C
153 Low limit temp: 75C
154 Max driver current: 1200mA
155 Max output current: 2000mA
156 ```
UT2UK 1.1 157
UT2UK 2.1 158 | Field | Description | Default value |
159 | ------------------ | --------------------------------------------- | ------------- |
160 | High limit temp | Maximum temperature (alarm) | 80°C |
161 | Low limit temp | Minimum temperature (restore) | 75°C |
162 | Max driver current | Max driver current (alarm threshold) | 1200mA |
163 | Max output current | Max output current (alarm threshold) | 2000mA |
164
UT2UK 1.1 165 ### Bias Table
166
UT2UK 2.1 167 ```bash
168 Bias DAC output 0: 2450
169 Bias DAC output 1: 2460
170 Bias DAC driver 0: 1850
171 Bias DAC driver 1: 1855
172 Target driver current,mA: 600
173 Target output current,mA: 1000
174 Driver thermo compensation,dac/C: -2
175 Output thermo compensation,dac/C: -3
176 Temprature of calibration,C: 25
177 ```
UT2UK 1.1 178
UT2UK 2.1 179 | Field | Description | Range |
180 | -------------------------- | --------------------------------------------------- | ------------------- |
181 | Bias DAC output [0/1] | DAC bias value for output channels 0 and 1 | 0-4095 |
182 | Bias DAC driver [0/1] | DAC bias value for driver channels 0 and 1 | 0-4096 |
183 | Target driver current | Target idle current for driver stage | 1-1000 mA |
184 | Target output current | Target idle current for output stage | 1-2000 mA |
185 | Driver thermo compensation | Driver thermal compensation | -100 to +100 DAC/°C |
186 | Output thermo compensation | Output thermal compensation | -100 to +100 DAC/°C |
187 | Temperature of calibration | Temperature at which calibration was performed | °C |
188
UT2UK 1.1 189 ### Fan Control Table
190
UT2UK 2.1 191 ```bash
192 Index | Temperature (°C) | Fan Speed (%)
193 ------|------------------|---------------
194 0 | 10 | 0%
195 1 | 20 | 7%
196 2 | 35 | 31%
197 3 | 40 | 63%
198 4 | 50 | 79%
199 5 | 60 | 100%
200 6 | 70 | 100%
201 7 | 126 | 100%
202 ```
203
UT2UK 1.1 204 The table contains 8 interpolation points. Each row contains:
205 * **Index**: sequence number (0-7)
206 * **Temperature**: threshold temperature in °C
207 * **Fan Speed**: fan speed in %
208
209 Speed is calculated by interpolating between points based on the current temperature.
210
211 ### Calibration Progress
212
213 During automatic calibration a progress bar is displayed:
214
UT2UK 2.1 215 ```bash
216 Tuning Driver Channel 0
217 Target Current: 600mA
218 DAC: 1800/4095 [***** ] 12% | Current: 150mA/600mA [**** ] 25%
219 ```
220
UT2UK 1.1 221 Components:
222 * **DAC**: current DAC value and maximum
223 * First progress bar: DAC progress (yellow)
224 * **Current**: current measured current and target current
225 * Second progress bar: progress toward target current (green)
226
227 ### Error Messages
228
UT2UK 2.1 229 ```bash
230 Set bias ON ERROR
231 Get driver current ERROR
232 Request PA config ERROR
233 Connect/Disconnect loading ERROR
234 Unable to tune bias for Driver channel 0
235 ```
236
UT2UK 1.1 237 An error message in red indicates a communication failure with PA Manager or an unexpected state.
238
239 ### Success Messages
240
UT2UK 2.1 241 ```bash
242 ✓ Finished OK
243 Channel: 0
244 Final DAC Value: 1850
245 Final Current: 600mA
246 Bias switched ON.
247 New settings were recorder to NVMEM - OK.
248 Overcurrent flag reseted OK.
249 ```
250
UT2UK 1.1 251 Successful operations are displayed in yellow.
252
253 ## Usage Examples
254
255 ### Example 1: Checking Amplifier Status
256
UT2UK 2.1 257 ```bash
258 $ patune
259 ************************************************************
260 | Power amplifier service utility version 1.2 |
261 ************************************************************
262 [Main menu]
263 0 - Print PA info.
264 1 - Print PA config.
265 2 - Print PA bias table.
266 3 - [Edit bias table]
267 4 - [Edit PA configs]
268 5 - [Edit fan table]
269 6 - Bias switch ON.
270 7 - Bias switch OFF.
271 8 - Reset overcurrent.
272 9 - Write all settings.
273 q - Quit
274 Enter your choice: 0
275 Print PA info.
276 Heat temp: 45C
277 Int temp: 38C
278 VSWR alarm : 0
279 Extra current alarm : 0
280 Temperature alarm : 0
281 Bias enable: 1
282 Bus voltage: 48mV
283 Output stage current: 1050mA
284 Driver stage current: 620mA
285 Output bias: 2450/2460mV
286 Driver bias: 1850/1855mV
287 Fan speed: 35
288 ```
289
UT2UK 1.1 290 ### Example 2: Setting Target Driver Current
291
UT2UK 2.1 292 ```bash
293 Enter your choice: 3
294 [Bias table editor]
295 0 - Print PA bias table.
296 1 - Reset all bias to default value.
297 2 - Enter driver stage current.
298 3 - Enter output stage current.
299 4 - Autotune DAC bias for driver stage.
300 5 - Autotune DAC bias for output stage.
301 6 - Print power consumption for all stages.
302 7 - Enter driver stage thermo compensation.
303 8 - Enter output stage thermo compensation.
304 q - Quit
305 Enter your choice: 2
306 Enter driver stage current, mA (1-1000), press 'q' to cancel: 650
307 ```
308
UT2UK 1.1 309 ### Example 3: Automatic Driver Calibration
310
UT2UK 2.1 311 ```bash
312 Enter your choice: 4
313 Tuning Driver Channel 1
314 Target Current: 600mA
315 DAC: 800/4096 [** ] 19% | Current: 0mA/600mA [ ] 0%
316 DAC: 1200/4096 [**** ] 29% | Current: 100mA/600mA [***** ] 16%
317 DAC: 1500/4096 [**** ] 36% | Current: 250mA/600mA [******* ] 41%
318 DAC: 1700/4096 [***** ] 41% | Current: 450mA/600mA [***** *** ] 75%
319 DAC: 1750/4096 [***** ] 42% | Current: 590mA/600mA [***** **** ] 98%
320 DAC: 1751/4096 [***** ] 42% | Current: 600mA/600mA [***** ***** ] 100%
321 ✓ Finished OK
322 Channel: 1
323 Final DAC Value: 1751
324 Final Current: 600mA
325 ```
326
UT2UK 1.1 327 ### Example 4: Editing a Fan Table Entry
328
UT2UK 2.1 329 ```bash
330 Enter your choice: 5
331 [Fan Table Editor]
332 0 - Print fan lookup table.
333 1 - Reset fan table to defaults.
334 2 - Edit entry 0 (10°C / 0%).
335 3 - Edit entry 1 (20°C / 7%).
336 ...
337 Enter your choice: 3
338 Edit Fan Table Entry 2
339 Current settings:
340 Temperature: 35°C
341 Fan Speed: 31%
342 Enter new temperature (C) (-40 - 126), press 'q' to cancel: 30
343 Enter new fan speed (0-100%) (0-100), press 'q' to cancel: 25
344 Entry 2 updated:
345 Temperature: 30°C
346 Fan Speed: 25%
347 ```
348
UT2UK 1.1 349 ### Example 5: Saving Configuration
350
UT2UK 2.1 351 ```bash
352 Enter your choice: 9
353 New settings were recorder to NVMEM - OK.
354 ```
355
UT2UK 1.1 356 ## Error Diagnostics
357
358 ### Calibration Error
359
360 **Message:**
361
UT2UK 2.1 362 ```bash
363 ✗ Unable to tune bias for Driver channel 0
364 ```
365
UT2UK 1.1 366 **Causes:**
367 * Amplifier is not functioning
368 * No power supply to the stage
369 * Current sensor is faulty
370 * Bias circuit is incorrectly configured
371
372 **Solution:**
373 1. Check PA power supply
374 1. Check load connectors
375 1. Make sure bias can be adjusted
376 1. Check the DAC coefficient value
377
378 ### Configuration Write Error
379
380 **Message:**
381
UT2UK 2.1 382 ```bash
383 Write config ERROR
384 ```
385
UT2UK 1.1 386 **Causes:**
387 * NVMEM is full
388 * Hardware write error
389 * Loss of connection with PA Manager
390
391 **Solution:**
392 1. Repeat the write operation
393 1. Try resetting the configuration: "Reset all bias to default value"
394 1. Reboot and try again
395
396 ## Practical Application Scenarios
397
398 ### Scenario 1: Initial Setup of a New Amplifier
399
UT2UK 2.1 400 ```
401 Step 1: Check status
402 - Select "Print PA info"
403 - Make sure the sensors are working
404 Step 2: Set target currents
405 - Select "Edit bias table" → "Enter driver stage current"
406 - Enter 600 mA (typical value)
407 - Select "Enter output stage current"
408 - Enter 1000 mA (typical value)
409 Step 3: Automatic calibration
410 - Select "Autotune DAC bias for driver stage"
411 - Wait for completion (both channels sequentially)
412 - Select "Autotune DAC bias for output stage"
413 - Wait for completion
414 Step 4: Verify results
415 - Select "Print PA info"
416 - Make sure currents are within target values
417 Step 5: Save
418 - Select "Write all settings"
419 ```
420
UT2UK 1.1 421 ### Scenario 2: Fan Control Setup
422
UT2UK 2.1 423 ```bash
424 Step 1: View current table
425 - Select "Edit fan table" → "Print fan lookup table"
426 Step 2: Edit interpolation points
427 - For each entry:
428 - Select "Edit entry N"
429 - Set the trigger temperature
430 - Set fan speed in %
431 Step 3: Save
432 - Select "Write all settings"
433 Example table for cold climate:
434 Entry 0: 15°C / 0%
435 Entry 1: 25°C / 10%
436 Entry 2: 40°C / 30%
437 Entry 3: 50°C / 60%
438 Entry 4: 60°C / 80%
439 Entry 5: 70°C /100%
440 Entry 6: 80°C /100%
441 Entry 7: 126°C /100%
442 ```
443
UT2UK 1.1 444 ### Scenario 3: Maintenance and Diagnostics
445
UT2UK 2.1 446 ```
447 Step 1: Check configuration integrity
448 - Select "Print PA bias table"
449 - Make sure all values are within acceptable limits
450 - Select "Print PA config"
451 Step 2: Check current consumption
452 - Select "Print power consumption for all stages"
453 - Compare with expected values
454 Step 3: Test the amplifier
455 - Select "Bias switch ON"
456 - Check "Print PA info"
457 - Make sure all alarms are in zero state
458 - Select "Bias switch OFF"
459 Step 4: Reset alarm (if required)
460 - Select "Reset overcurrent"
461 ```
462
UT2UK 1.1 463 ## Limitations and Implementation Notes
464
465 ### Parameter Limits
466
UT2UK 2.1 467 | Parameter | Minimum | Maximum | Note |
468 | ---------------------------------- | ------- | ------------------------------ | --------------------- |
469 | Driver current | 1 mA | 1000 mA | Target value |
470 | Output current | 1 mA | 2000 mA | Target value |
471 | Max alarm current (driver) | - | 6000 mA | Threshold value |
472 | Max alarm current (output) | - | 26000 mA | Threshold value |
473 | Heatsink temperature | -40°C | 126°C | Sensor range |
474 | Maximum alarm temperature | - | 80°C | Limited |
475 | Bias DAC | 0 | 4095 (output) / 4096 (driver) | 12-bit resolution |
476 | Thermal compensation | -100 | +100 | DAC/°C |
477 | Fan speed | 0% | 100% | Corresponds to DAC 0-63 |
UT2UK 1.1 478
479 **Utility version:** 1.2