1 -To start calibration, press the {{html}}<span style="border-radius:4px;font-size:100%;font-weight:bold;background-color:#007bff;" class="badge bg-info">GEN</span>{{/html}} button while in the transmitter operational settings window.
1 +Для старта калибровки  необходимо  нажать кнопку {{html}}<span style="border-radius:4px;font-size:100%;font-weight:bold;background-color:#007bff;" class="badge bg-info">GEN</span>{{/html}} нааходясь в окне оперативных настроек передатчика
2 +
2 2  (% class="box infomessage" %)
3 3  (((
4 -== Important! ==
5 +== Важно! ==
6 +
5 5  ----
6 -**A 50 Ohm output load capable of handling 100 Watts of applied power in CW mode and an external power meter MUST be connected to the transceiver output.**
8 +
9 +**К выходу трансивеар ОБЯЗАТЕЛьНО необходимо подключить выходную нагрузку 50 Ом, выдерживающую подведенную мощность 100 Ватт в режиме CW и измеритель мощности.**
7 7  )))
8 -A warning message will appear on the screen:
9 -[[image:1772386287094-347.jpeg||height="450" width="800"]]
10 -When the {{html}}<span style="border-radius:4px;font-size:100%;font-weight:bold;background-color:#007bff;" class="badge bg-info">OK</span>{{/html}} button is pressed, the transceiver will enter transmission mode and output a tonal carrier.
11 -The output power of the tonal carrier is the current transmitter power level **(TX POWER)** set before entering calibration mode.
12 -[[image:1772386544846-753.png||height="395" width="800"]]
13 -By adjusting the **{{html}}<span style="font-size:100%;font-weight:bold; background-color: #28a745;" class="badge bg-dark">RF</span>{{/html}}** encoder, achieve equality between the **ACTUAL** output power (measured by the external power meter) and the pre-set **TX POWER** value.
14 -When the {{html}}<span style="border-radius:4px;font-size:100%;font-weight:bold;background-color:#007bff;" class="badge bg-info">GEN</span>{{/html}} button is pressed again, or when exiting the transmitter operational settings window, the current calibration is saved to NVMEM memory and the device returns to receive mode.
15 -(% class="box infomessage" %)
16 -(((
17 -**The transmitter output power calibration must be repeated for all amateur radio bands!**
18 -)))
11 +