Wiki source code of Calibration of PA by bands

Last modified by UT2UK on 2026/03/02 10:13

Show last authors
1 To start calibration, press the {{html}}<span style="border-radius:4px;font-size:100%;font-weight:bold;background-color:#007bff;" class="badge bg-info">GEN</span>{{/html}} button while in the transmitter operational settings window.
2
3 (% class="box infomessage" %)
4 (((
5 == Important! ==
6
7 ----
8
9 **A 50 Ohm output load capable of handling 100 Watts of applied power in CW mode and an external power meter MUST be connected to the transceiver output.**
10 )))
11
12 A warning message will appear on the screen:
13
14
15 [[image:1772386287094-347.jpeg||height="450" width="800"]]
16
17
18 When the {{html}}<span style="border-radius:4px;font-size:100%;font-weight:bold;background-color:#007bff;" class="badge bg-info">OK</span>{{/html}} button is pressed, the transceiver will enter transmission mode and output a tonal carrier.
19 The output power of the tonal carrier is the current transmitter power level **(TX POWER)** set before entering calibration mode.
20
21
22 [[image:1772386544846-753.png||height="395" width="800"]]
23
24
25 By adjusting the **{{html}}<span style="font-size:100%;font-weight:bold; background-color: #28a745;" class="badge bg-dark">RF</span>{{/html}}** encoder, achieve equality between the **ACTUAL** output power (measured by the external power meter) and the pre-set **TX POWER** value.
26 When the {{html}}<span style="border-radius:4px;font-size:100%;font-weight:bold;background-color:#007bff;" class="badge bg-info">GEN</span>{{/html}} button is pressed again, or when exiting the transmitter operational settings window, the current calibration is saved to NVMEM memory and the device returns to receive mode.
27
28
29 (% class="box infomessage" %)
30 (((
31 **The transmitter output power calibration must be repeated for all amateur radio bands!**
32 )))